FIXED HINGE LEAF
Design Agency · studio CAD sample
https://designagency.dev/work/hinge-leaf-cad-sample/

Open fixed-hinge-leaf.step in a solid modeller to inspect the part, measure
its features or edit its faces. The file contains one boundary-representation
solid. Open fixed-hinge-leaf.stl in a slicer, with the import units set to
millimetres. The STL represents the same leaf with 13,086 triangles.

fixed-hinge-leaf-plan.svg is a dimensioned plan view showing the countersunk
face. Open it in a browser and zoom in to inspect the hole locations.

NOMINAL GEOMETRY
All dimensions are in millimetres.

Overall envelope              72 along the pin × 36 across the leaf × 12 high
Plate thickness               3
Pin centreline to free edge   30
Knuckles                      3, each 14 long, with 15 between adjacent ends
Knuckle outer diameter        12
Coaxial bore diameter         5.6
Mounting holes                3 × Ø4.4 through
Countersinks                  Ø8 at the upper plate face, 90° included angle
Countersink depth             1.8

MOUNTING HOLE CENTRES
In the plan view, measure from the left end of the leaf along the pin axis,
then from the pin centreline towards the free edge.

Hole       Along the axis        Towards the free edge
Left            11.52                    21.60
Middle          36.00                    16.50
Right           60.48                    21.60

MODEL CHECK
The STEP file reopened as one valid solid with a volume of 8,726.072 mm³.
The STL uses the original studio mesh coordinates. A mesh approximates
curved surfaces, so fine measurements should be taken from the STEP solid.

MODEL YOUR OWN PART
https://designagency.dev/cad-modelling/
https://designagency.dev/brief.html?service=cad